Fire Hydrant Protection System is designed to fight fire of huge proportions, in all classes of risks. It is designed to be in operation even if a part of the affected structure collapses.
The Hose Reel should normally be located in occupied units/areas to enable the occupants of the building to attack a fire. However, in case of a building having a number of small units, hose reels may be located in common areas immediately outside the occupied units/areas on that floor to provide coverage.
The automatic Sprinkler Systems is the most widly used fire production system today and have been used to protect lives and property. The systems are designed to provide immediate fire defence when a fire occurs to protect lives and minimize material losses in the event of a fire.
Fire detection and alarm systems detect the initial smoke or heat released from a fire to provide an early warning, 24 hours a day, 7 days a week, allowing permises to be evacuated, emergency services notified and plant to be shut down / activated as necessary. Manual call points ("Break glass" devices) can be fitted to they system a strategic locations to allow manual activation of the alarm system.
The Clean Agent Fire Suppression System is made up of a cylinder filled with the clean agent, a piping network, and discharge nozzles. The cylinder containing the clean agent is the most critical component of the system, and it needs to be maintained and tested regularly to ensure it remains functional. Our Clean Agent Fire Suppression Systems are designed to protect critical assets and high-value equipment in environments where water-based fire suppression systems cannot be used. This system uses clean agents like FM-200 or Novec 1230 and These agents are classified as suitable for use in occupied areas and are considered to have no ozone depleting potential (ODP) which are non-conductive, non-corrosive, and leave no residue. For speed in suppressing fires, reducing damages, saving on floor space and allowing visibility,DFF is the clear choice, and it discharge in 10 seconds or less, extinguishing a fire quickly and effectively.
The Automatic Fire Tube fire suppression system is Tube based suppression system which is used clean agent to extinguish the electrical fires in control panels. The system comprises of a cylinder charged with the extinguishing agent, actuation valve with pressure gauge and the single heat-sensitive polymer heat and fire detection tube. The polymer heat and fire detection tube is red in color, flexible and can be routed inside the cabinets or equipments – close to the point of fire risk.
As part of any fire strategy, there is likely to be a requirement for supplementary extinguishing or safety systems to be used by individuals (or operated remotely) to attack the blaze at the point that it occurs Fire extinguishers are located in many buildings, containing the relevant extinguishant subject to the hazards present in the area as one of the cornerstones of most fire strategies.
The high pressure fire fighting equipment based on water mist technology and it's to be mounted on pick up vehicle carriers can be used as water mist fire tender.
Water mist fire tender does quick transportation of Fire Fighter to an incidental scene, providing water and foam with which to fight a fire and carrying equipment needed by the Fire Fighter. It plays a critical role in situations, where medium and large fire trucks are difficult to mobilize due to narrow passage.
Foam Compound Storage tanks are used in fixed foam systems for storage of foam compound at atmospheric pressure, in the required quantity. These storage tanks are used in conjunction with Inline Inductors, Balanced Pressure proportioning or other foam proportioning systems.
Foam compound Storage Tanks, made of Stainless Steel - SS 304, storage capacity (as specified by client), and shall incorporate regular design features such as expansion dome (for above 400 ltrs. capacity), sump at bottom of tank, vent valves, inlet and outlet connections, PV vent, etc. Level gauge (optional) can be provided.
Installing fire-rated doors in homes and offices is essential to maximize safety in the event of a fire. Today, Fire Doors have been made a mandatory requirement & have established acceptance in high rise buildings, Commercial Buildings, Cinema Halls, Auditoriums, and various Industries including Refineries, Steel Plants, Aluminum Plants, Nuclear Power Stations, Fertilizer Units, Cotton Mills etc.
Heating, ventilation, and air conditioning (HVAC) is the technology of indoor and vehicular environmental comfort. Its goal is to provide thermal comfort and acceptable indoor air quality.
HVAC system design is a subdiscipline of mechanical engineering, based on the principles of thermodynamics, fluid mechanics and heat transfer.
Personal Protective Equipment is designed to protect firefighters from serious injuries or illnesses resulting from contact with chemical, radiological, physical, electrical, mechanical or other hazards.
It covers a variety of devices and garments such as respirators, turnout gear, gloves, blankets and gas masks.
We provide the refilling services for clean agent gases(i.e : NOVEC 1230/ FM 200 gas), we follows highly safest standred and effecient methods to refilling the gases in the fire suppression system .
We Offer the door step service to refilling the fire suppression system who needs the services
We provide complete range of Fire & Safety services which includs follows:
Dolphin Fire Fighters (DFF) is a leading Fire Protection Engineering, Supply and Service provider,It's provides complete range of Fire Protection Services throughout India.
Dolphin is headed by a team of experienced technocrats having varied and extensive experience and we do engineering, constructions, installation and testing of fire safety system (Fire Protection) and we have a well established track record and our services have always met with great customer satisfaction.
Consoltation of Fire saftey system design & engneering accorandess with as per standard norms (i.e. NBC-Indian, NFPA, UL/FM).
Fire System Supply, Installation, Commissioning and Testing.
Complete new installation & AMC for fire alram system, fire hydrant system, CCTV systems, Access Control System and refilling of fire extinguisher.
Fire safety NOC for Commericial buildings, Industries, Hospitals, Education Institute, Government buildings (i.e.etc,).